  • Measuring transducer for three-phase generator input

  • Simple application; for harsh environments

  • Compact design for mounting side by side

  • Fine adjustment of the measuring range via sealed integrated trimming potentiometer

  • Operating status indication via integrated LED

Measuring transducers of type VFW5 convert the signal from a 24 V three-phase generator into standardised output signals. They are mounted on G rails or top-hat rails. The sensor input and supply voltage for the output signal are galvanically isolated. Its compact and robust design, as well as the relevant shipbuilding approvals, make this product ideal for marine applications.

Supply voltage UB

UB via terminal W of a three-phase generator

Input signal

Terminal W of a 24 V three-phase generator

Output signal

0 ... 10 V/DC (VFW5..-G1), 2 ... 10 V/DC (VFW5..-G2) short-circuit proof, load current max.20 mA; 0 ... 20 mA (VFW5..-I1), 4 ... 20 mA (VFW5..-I2), load resistance 0 ... 500 Ω

Operating temperature

-20°C ... +70°C

Connection

DIN EN 46244 tab connector, gold-plated A6,3 x 0.8

Mounting

TS32 G-rail or TS35 top hat rail

Part code structure

VFW5

01

-I2

-352

Example: VFW501-I2-352

Input signal

Output signal

Upper-range frequency

Part code VFW5 …

Input signal

00

0 … 100 Hz

01

0 … 1,200 Hz

Output signal

-G1-

Output 0 … 10 V DC, short-circuit proof

-G2-

Output 2 … 10 V DC, short-circuit proof

-I1-

Output 0 … 20 mA

-I2

Output 4 … 20 mA

Upper-range frequency

-…

Upper-range frequency in Hz (= 20 mA or 10 V)

VFW5

__

-__

-__

Example: VFW501-I2-352