  • Typical application: Shipbuilding (Propulsion & Power)

  • Simple, direction-independent installation

  • Very large gears can be scanned

  • Thread sizes (including special threads) customized according to customer requirements

Speed sensors of type FA13 are non-contacting one- or two-channel speed encoders with a stainless steel threaded tube. They measure frequency in accordance with the difference-hall-effect principle (FAH type) or inductive-magnetic principle (FAJ type). These speed sensors are suitable for scanning ferromagnetic materials, e.g., toothed wheels with various tooth shapes, screw heads, drill holes, apertures, grooves or pulse bands on smooth shafts (accessories). Its compact and robust design, as well as the relevant shipbuilding approvals, make this product ideal for marine applications.

FA13 Overview

Type

Measuring principle

Signal outputs

Signal form

FAH13

Difference-Hall

One square wave signal

Signalform FAx1x_Q1

FAJ13

Induct.-magnetic

One square wave signal

Signalform FAx1x_Q1

FAHZ13

Difference-Hall

Two square wave signals,
Q2 to Q1 is 90° phase shifted

FAxZ Phasendiagramm

FAHS13

Difference-Hall

Two square wave signals,
Q2 to Q1 is 90° phase shifted,
one rotation direction signal

FAxS Phasendiagramm

FAHD13

Difference-Hall

Two square wave signals,
galvanically isolated,
Q2 to Q1 is 90° phase shifted

FAxD Phasendiagramm galvanisch getrennt

FAHQ13

Difference-hall

Two + Two inverted square wave signals, Q1 to Q2 and Q1_N to Q2_N are 90° phase shift

FAxQ Phasendiagramm

FA13 – Approvals

Approvals

Logo_Klasse_ABS

Logo_Klasse_BV

Logo DNV

Logo_Klasse_LR

Supply voltage UB

9 ... 32 VDC

Frequency range

Type FAH13: 0.2 ... 20,000 Hz
Type FAJ13: 5 … 10,000 Hz

Measuring channels

According to sensor type:
1 measuring channel
2 measuring channels
2 galvanically isolated measuring channels
2 measuring channels plus status channel rotational direction

Output signals and signal form

Depending on the sensor type, cf. description

Scanning object

Ferromagnetic materials
Additional information in the datasheet

Distance scan object

Type FAH13: 0.2 ... 3 mm; recommended: 1.0 ± 0.5 mm
Type FAJ13: cf. datasheet

Operating temperature

-40 … +120°C

Degree of protection

Housing: IP66/IP68/IP69

List with female connector type and order No.

Connector

Drawing No.

Order No.

Female connector DIN 43650-A

ZL-3A

311046

Female connector according VG95234

ZL4-1A-E

314015

Female connector Euro M12x1, shielded, straight with 2.0 m cable

ZL4-2A

522101

Female connector Euro M12x1, shielded, straight with 5.0 m cable

ZL4-2A

522102

Female connector Euro M12x1, shielded, straight with 10.0 m cable

ZL4-2A

522109

Female connector Euro M12x1, shielded, angled 90°, with 2.0 m cable

ZL4-2A

522439

Female connector Euro M12x1, shielded, angled 90°, with 5.0 m cable

ZL4-2A

522438

Female connector Euro M12x1, shielded, angled 90°, with 10.0 m cable

ZL4-2A

522437

Type code structure

FA

H

Z

13-

02

15-

X03-

M10-

S0

Example: FAHZ13-0215-X03-M10-S0

Measuring principle

Measuring principle supplement

Construction type & material

Nominal length L1 and L2 of the sensor tube

Thread type

Electrical connection

Module version

Shield

Type code FAJ13[..]

Measuring principle

J

Inductive-magnetic

Measuring principle supplement

Without code: 1 output signal

Construction type & material

13-

Sensor tube: Stainless steel

Nominal length

02

L1 = 60 mm, L2 = 5 mm

03

L1 = 80 mm, L2 = 5 mm

04

L1 = 100 mm, L2 = 20 mm

05

L1 = 120 mm, L2 = 40 mm

Other lengths up to 200 mm available on request

Thread type

13-

M14 x 1

22-

M16 x 1.5

15-

M18 x 1

23-

M18 x 1.5

88-

5/8‘‘ – 18 UNF

Electrical
connection

A-

DIN43650-A pin connector

C-

MIL 14-5PN VG95234 pin connector

E-

Euro M12x1 pin connector

H1-

DIN72585 Bayonet

X03-

Cable end with sheath length 0.5 m

X05-

Cable end with sheath length 2.0 m

X06-

Cable end with sheath length 3.0 m

X07-

Cable end with sheath length 5.0 m

X08-

Cable end with sheath length 7.5 m

X09-

Cable end with sheath length 10.0 m

Shield

Without code: Shield attached to the sensor housing

S0

Shield not attached to the sensor housing

FA

_ _

_ _

_ _-

_ _

_ _-

_ _-

_ _

Example: FAJ13-0323-E-S0

Customer-specific types