Search

FAHU52

FAHU52

FAHU52

  • Typical application areas: railway technology (light & heavy rail) and special machine construction (mining)

  • Frequency detection on ferromagnetic scanning objects according to the Hall principle

  • Lifecycle cost optimized: wear and maintenance-free through contactless scanning, high durability through robust design

  • Robust design for risk-free installation and harsh environmental conditions

  • Good suitability for safety applications, e.g., fire protection according to EN 45545

  • Up to 4 measuring channels can be galvanically isolated in a single housing. Voltage signals or current output signals can be featured in any combination.

Type FAHU52 speed sensors are non-contacting three- or four-channel speed sensors with a stainless-steel flange and sensor tube. They measure frequency in accordance with the Hall-effect principle. They acquire the speed of ferromagnetic objects, e.g., toothed wheels with various tooth shapes, screw heads, bore holes, apertures, grooves or pulse bands on smooth shafts (accessories). Their compact and robust design, as well as the relevant tests as per DIN EN 50155, make them ideal for applications in the field of transport technology, e.g., measuring speed at the traction motor, gearbox or wheel set. The sensors are available with different output signals (voltage or current output).

Overview speed sensors FAHU52

Typ

Measuring principle

Signal outputs

Signal form

FAHU52[..]-U01

Hall

Four galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Type –U01: voltage output
Type –U11: current output

FAHU[..]-U01 Phasendiagramm

FAHU52[..]-U11

FAHU52[..]-U02

Hall

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Type –U02: voltage output
Type –U12: current output

FAHU[..]-U02 Phasendiagramm

FAHU52[..]-U12

FAHU52[..]-U03

Hall

Two galvanically isolated measuring systems, each with two square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Type –U03: voltage output
Type –U13: current output

FAHU[..]-U03 Phasendiagramm

FAHU52[..]-U13

FAHU52[..]-U21

Hall

Four galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Q1, Q2 with voltage output
Q3, Q4 with current output

FAHU[..]-U01 Phasendiagramm

FAHU52[..]-U22

Hall

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Q1, Q2 with voltage output
Q3, Q4 with current output

FAHU[..]-U02 Phasendiagramm

FAHU52[..]-U23

Hall

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Q1, Q2 with current output
Q3, Q4 with voltage output

FAHU[..]-U02 Phasendiagramm

FAHU52[..]-U24

Hall

Two galvanically isolated measuring systems, each with two square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted

Q1, Q2 with voltage output
Q3, Q4 with current output

FAHU[..]-U03 Phasendiagramm

Supply voltage UB

9 ... 32 VDC

Frequency range

Difference-Hall principle:0 ... 25,000 Hz

Measuring channels

1 or 2 measuring channel

Output signals and signal form

Depending on the sensor type:
2 square wave signals or
2 square wave signals, 1 status signal or
2 square wave signals, 2 inverted square wave signals

Scanning object

Ferromagnetic materials

Distance scan object

0.2 ... 3 mm; recommended: 1.0 ± 0.5 mm

Operating temperature

-40 … +120°C
Variants with current output: -40 … +100°C

Degree of protection

Housing: IP66/IP68/IP69

Type code structure

FA

H

U

52-

11-

S

X

07-

M30-

S0-

U01

Example: FAHU52-11-SX07-S0-U01

Measuring principle

Measuring principle supplement

Construction type and material

Nominal length L1 of the sensor tube

Connection outlet

Electrical connection

Cable length

Module

Shield

Signal variant

Type code FAHU52

Measuring principle

H

Difference-Hall

Measuring principle
supplement

U

4 output signals, galvanically isolated

Construction type and material

52-

Flange, stainless steel sensor tube

Nominal length

11-

L1 = 29 mm

Connection outlet

Without code: straight cable outlet

S

Lateral cable outlet

Electrical connection

X

Cable end standard (without protective tubing)

XGS

Cable end, protective tubing, steel reinforced

XGT

Cable end, protective tubing, textile reinforced

XP

Cable end, protective tubing, polyamide

Sheath length

05-

Sheath length 2.0 m, halogen-free

07-

Sheath length 5.0 m, halogen-free

08-

Sheath length 7.5 m, halogen-free

09-

Sheath length 10.0 m, halogen-free

Module

M10-

Module m1

M12-

Module m1.25

M15-

Module m1.5

Without code: Module m2

M25-

Module m2.5

M30-

Module m3

Shield

Without code: Shield attached to the sensor housing

S0-

Shield not attached to the sensor housing

Signal variants

Uxx

Output signal variants (xx see next table)

FA

_ _

_ _

_ _-

_ _-

_ _

_ _

_ _-

_ _-

_ _-

_ _

Example:
FAHU52-11-X07-U01

Customer-specific types

If you don’t find anything suitable among our standard types, we’ll be happy to develop a tailored solution with you to meet your requirements (-P types). They also meet the abovementioned standards thanks to our type-approved modular kits.

Code

Output signal variant

U01

Four galvanically isolated output signals (voltage)

U11

Four galvanically isolated output signals (current)

U02

Two output signals + two galvanically isolated output signals (voltage)

U12

Two output signals + two galvanically isolated output signals (current)

U03

Two galvanically isolated measuring systems, each with two output signals (voltage)

U13

Two galvanically isolated measuring systems, each with two output signals (current)

U21

Four galvanically isolated output signals (Q1, Q2 voltage; Q3, Q4 current)

U22

Two output signals + two galvanically isolated output signals (Q1, Q2 voltage; Q3, Q4 current)

U23

Two output signals + two galvanically isolated output signals (Q1, Q2 current; Q3, Q4 voltage)

U24

Two galvanically isolated measuring systems, each with two output signals (Q1, Q2 voltage; Q3, Q4 current)