  • Typical application areas: shipbuilding (e.g., drive shafts and flywheels)

  • Particularly good price-performance ratio

  • Robust design for risk-free installation and harsh environmental conditions, high resistance against shock and vibration

  • Very high immunity to electromagnetic interference (EMI)

  • Robust design with high resistance to vibration and shock

  • Straight or lateral cable exit, available with cable protection system

Speed sensors of type FA5 are non-contacting 2-channel hall effect encoders with a stainless-steel sensor tube. This solution has been established on the market for a long time and has proven to be very effective in a wide range of applications.

The sensors are available with various output signals:

Type

Measuring principle

Output signals

Signal type

FAHZ5

Difference-Hall

2 square wave signals,
Q2 to Q1 by 90° phase shift

FAxZ Phasendiagramm

FAHS5

Difference-Hall

2 square wave signals,
Q2 to Q1 90° phase shift,
1 status signal for rotational direction detection

FAxS Phasendiagramm

FAHD5

Difference-Hall

2 square wave signals,
Q2 to Q1 90° phase shift,
signals galvanically isolated

FAxD Phasendiagramm galvanisch getrennt

FAHQ5

Difference-Hall

4 square wave signals,
Q2 to Q1 90° phase shift,
Q1_N and Q2N are inverted signals of Q1 and Q2

FAxQ Phasendiagramm

Supply voltage UB

9 ... 32 VDC

Frequency range

0.2 ... 20,000 Hz

Measuring channels

According to the type:
2 measuring channels
2 galvanically isolated measuring channels
2 measuring channels plus status channel rotational direction

Output signals and signal form

Depending on the sensor type, cf. description

Scanning object

Ferromagnetic materials
Toothed wheel: Module m1 to m3; tooth face width ≥ 7 mm (spur gear DIN867)

Distance scan object

0.2 ... 3 mm; recommended: 1.0 ± 0.5 mm

Operating temperature

-40 … +120°C

Degree of protection

Housing: IP66/IP68
Connection: IP66/IP68

Type code structure

FA

H

Z

5-

11-

S

X

07-

M30-

S0

Example: FAHZ5-11-SX07-M30S0

Measuring principle

Measuring principle supplement

Construction type and material

Nominal length L1 of the sensor tube

Connection outlet

Electrical connection

Cable length

Module

Shield

FAH[..]5 part code

Measuring principle

H

Difference-Hall

Measuring principle extension

Z

2 Output signals (voltage)

D

2 Output signal (voltage), galvanically isolated

S

2 Output signals (voltage) + status signal output for rotational direction detection

Q

4 Output signals (voltage, 2 + 2 inverted)

Model and material

5-

Sensor tube, chromatised aluminium

Nominal length

11-

L1 = 29 mm

Connector output

No identifier: straight connector outlet

S

Lateral connector output

Electrical
connection

X

Standard cable end (without protective tube)

XGS

Cable end, protective tube, reinforced with steel braiding

XGT

Cable end, protective tube, reinforced with textile fibre braiding

XP

Cable end, protective tube, polyamide

Jacket length

05-

Jacket length 2.0 m, halogen-free

07-

Jacket length 5.0 m, halogen-free

08-

Jacket length 7.5 m, halogen-free

09-

Jacket length 10.0 m, halogen-free

Module

M10-

Module m1

M12-

Module m1.25

M15-

Module m1.5

No identifier, Module m2

M25-

Module m2.5

M30-

Module m3

Shield

No identifier: Shield applied to sensor housing

S0

Shield applied to sensor housing

FA

_ _

_ _

_ _-

_ _-

_ _

_ _

_ _-

_ _-

_ _

Example:
FAHZ5-11-X07

Customer-specific types

If you don’t find anything suitable among our standard types, we’ll be happy to develop a tailored solution with you to meet your requirements (-P types). They also meet the abovementioned standards thanks to our type-approved modular kits.