Measuring transducer for frequency (square wave signal)
Measuring transducers of type VF5..KD convert frequencies (square wave signals) into standardised output signals. They are mounted on G rails or top-hat rails. The sensor input and supply voltage for the output signal are galvanically isolated. The compact and robust design, as well as the relevant tests as per DIN EN 50155, make the product ideal for applications in the field of transport technology.
Supply voltage Us | 9...32 VDC |
Input signal | Square wave signals |
Output signal | 0 ... 10 V/DC (VF5..KD.-G1), 2 ... 10 V/DC (VF5..KD.-G2), short-circuit-proof, load current 20 mA max.; 0 ... 20 mA (VF5..KD.-I1), 4 ... 20 mA (VF5..KD.-I2), load resistance 500 Ω max. |
Operating temperature | -20 °C ... +70 °C |
Connection | DIN EN 46244 gold-plated tab connector A6.3 x 0.8 |
Mounting | TS32 G-rail or TS35 top-hat rail |
Downloads
Type code structure | ||||
---|---|---|---|---|
VF5 | 01 | -KD99 | -I2 | Example: VF501-KD99-I2 |
Input range fr / limit frequency fl | ||||
| Tyre type / maximum velocity type | |||
| Output signal |
Type code VF5..-KD | |||||
---|---|---|---|---|---|
Input range fr/ limit frequency fl | 00 | fr: 10 … 100 Hz, fl: 50 … 100 Hz |
| ||
01 | fr: 20 … 1,000 Hz, fl: 100 … 1,000 Hz |
| |||
02 | fr: 200 … 10,000 Hz, fl: 1,000 … 10,000 Hz |
| |||
Tyre type / maximum velocity type |
| KDx | With setting option for tyre diameter |
| |
Output signal |
| -G1- | Output 0 … 10 V DC, short-circuit proof |
| |
-G2- | Output 2 … 10 V DC, short-circuit proof |
| |||
-I1- | Output 0 … 20 mA |
| |||
-I2 | Output 4 … 20 mA |
| |||
VF5 | __ | -__ | -__ | Example: VF501-KD99-I2 |